Home
World Journal of Advanced Research and Reviews
International Journal with High Impact Factor for fast publication of Research and Review articles

Main navigation

  • Home
  • Past Issues

Analytical method development and validation analysis for quantitative assessment of cypermethrin by HPLC procedure

Breadcrumb

  • Home
  • Analytical method development and validation analysis for quantitative assessment of cypermethrin by HPLC procedure

Supraja B 1, *, Giridhar C 2, Venkata Lakshmi V 3 and VenkataSubba Naidu N 4

1 Research Scholar, Department of Chemistry, S. V. University, Tirupati, Andhra Pradesh, India.
2 Assistant Professor, Department of Chemistry, Sri Venkateswara Engineering College, Nellore, Andhra Pradesh, India.
3 Sr. Lecturer, Department of Chemistry, S.G.S Arts College, Tirupati, Andhra Pradesh, India.
4 Professor, Department of Chemistry, S. V. University, Tirupati, Andhra Pradesh, India.

Research Article
 

World Journal of Advanced Research and Reviews, 2022, 14(01), 541–553
Article DOI: 10.30574/wjarr.2022.14.1.0352
DOI url: https://doi.org/10.30574/wjarr.2022.14.1.0352

Received on 19 March 2022; revised on 23 April 2022; accepted on 25 April 2022

The precise, systematic, definite, particular, linear, exact and robust scientific method was developed and validated for the assay of Cypermethrin in Cypermethrin 25% EC Insecticide for Injection, USP 500 mg/vial. Presently utilized Cypermethrin 25 % EC Insecticide as a working standard having limit was 95% for method development and validation. The quantitative determination bring to accomplished by HPLC- Waters - Alliance 510 system equipped with UV/PDA detector. Methanol, Acetonitrile and water in the ratio (60:20:20 v/v/v) used as mobile phase and flow rate 1.0 ml / min. with 20 minutes run time. The detection was carried at 225 nm with Nucleosil C18 column (250 mm × 4.6 mm x 10 µm) and ambient column temperature was maintained. In this connection, method uses the 20 μl injection volume and diluent as a blank solution. The linearity of this method was found to be linear in the range of 50% to 150% of the working concentration and the range for the analytical method is 25 ppm to 75 ppm. The accuracy and precision of the method were within acceptable. The present developed HPLC method is found to be suitable. The analytical solution was found to be stable up to 48 Hrs at room temperature.

Cypermethrin; Robust; Precision; Linearity; Stability

https://wjarr.co.in/sites/default/files/fulltext_pdf/WJARR-2022-0352.pdf

Preview Article PDF

Supraja B, Giridhar C, Venkata Lakshmi V and VenkataSubba Naidu N. Analytical method development and validation analysis for quantitative assessment of cypermethrin by HPLC procedure. World Journal of Advanced Research and Reviews, 2022, 14(01), 541–553. Article DOI: https://doi.org/10.30574/wjarr.2022.14.1.0352

Copyright © 2022 Author(s) retain the copyright of this article. This article is published under the terms of the Creative Commons Attribution Liscense 4.0

Footer menu

  • Contact

Copyright © 2026 World Journal of Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution