Home
World Journal of Advanced Research and Reviews
International Journal with High Impact Factor for fast publication of Research and Review articles

Main navigation

  • Home
  • Past Issues

Kinetics of the effect of the auricular heart point on the pressure-volume curve of the digital pulse

Breadcrumb

  • Home
  • Kinetics of the effect of the auricular heart point on the pressure-volume curve of the digital pulse

Gloria Patricia Guadalupe-Granados 1, Moisés Salvador Castañeda-Ramírez 2 and José Federico Rivas-Vilchis 2, *

1 Specialization in Acupuncture and Phytotherapy, Iztapalapa Campus, Metropolitan Autonomous University, México.
2 Department of Health Sciences, Iztapalapa Campus, Metropolitan Autonomous University, México.

Research Article
 

World Journal of Advanced Research and Reviews, 2024, 24(03), 1748-1756
Article DOI: 10.30574/wjarr.2024.24.3.3864
DOI url: https://doi.org/10.30574/wjarr.2024.24.3.3864

Received on 08 November 2024; revised on 16 December 2024; accepted on 18 December 2024

Introduction: The Heart auricular point has been shown to modify the characteristics of the digital pulse wave experimentally. However, kinetic studies have yet to widely evaluate its cardiovascular effects. The objective of this study was to propose an acukinetic model of the Heart auricular point effect using polynomial linear interpolation or spline.
Methods: The digital volume pulse was recorded in healthy subjects. A photoplethysmography transducer was placed on the index finger of the right hand. The signal was modulated and amplified using the MP150 amplifier processor. A continuous 70-s recording was taken consisting of a 30-s baseline (1–30 s), a 10-s transacupuncture (31–40 s), and a 30-s post acupuncture periods (41–70 s). Participants received acupuncture at the Heart point of the right ear. The needle was inserted to a depth of approximately 3 mm, with no additional stimulation; and remained inserted for 10 s. Derivatives and integrals of each pulse cycle during transacupuncture periods were solved. The peak slope values and area under the curve of the transacupuncture period were used to construct an interpolated curve.
Results: Analysis of spline curves during the transacupuncture period showed a decrease in their values in the initial period of auriculopuncture stimulation, with a recovery in the second part. These results may indicate that auriculopuncture initially reduced cardiac output, possibly causing a secondary sympathetic response mediated by baroreceptors.
Conclusion: These results may indicate that auriculopuncture initially reduced cardiac output, possibly causing a secondary sympathetic response mediated by baroreceptors.

Auricular point Heart; Photoplethysmography; Cardiovascular physiology; Digital volume pulse

https://wjarr.com/node/16976

Get Your e Certificate of Publication using below link

Download Certificate

Preview Article PDF

Gloria Patricia Guadalupe-Granados, Moisés Salvador Castañeda-Ramírez and José Federico Rivas-Vilchis. Kinetics of the effect of the auricular heart point on the pressure-volume curve of the digital pulse. World Journal of Advanced Research and Reviews, 2024, 24(03), 1748-1756. Article DOI: https://doi.org/10.30574/wjarr.2024.24.3.3864

Copyright © 2024 Author(s) retain the copyright of this article. This article is published under the terms of the Creative Commons Attribution Liscense 4.0

Footer menu

  • Contact

Copyright © 2026 World Journal of Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution