Home
World Journal of Advanced Research and Reviews
International Journal with High Impact Factor for fast publication of Research and Review articles

Main navigation

  • Home
  • Past Issues

A proposed equation estimating the length of peripherally inserted central catheter in hand for NICU hospitalized preterm neonates

Breadcrumb

  • Home
  • A proposed equation estimating the length of peripherally inserted central catheter in hand for NICU hospitalized preterm neonates

MahbodKaveh 1, 2, Mohammad SadeghArabhosseini 1, Mohammad Reza Zarkesh 3, 4, *, MokaramehHaghjoo 4, MaedehRaznahan 2 and Zahra Farahani 3

1 Department of Pediatrics, Bahrami Hospital, Tehran University of Medical Sciences, Tehran, Iran.
2 Breastfeeding Research Center, Tehran University of Medical Sciences, Tehran, Iran.
3 Maternal, Fetal and Neonatal Research Center, Tehran University of Medical Sciences, Tehran, Iran.
4 Department of neonatology, Yas Women Hospital, Tehran University of Medical Science, Tehran, Iran.

Research Article
 

World Journal of Advanced Research and Reviews, 2021, 11(01), 044-050
Article DOI: 10.30574/wjarr.2021.11.1.0313
DOI url: https://doi.org/10.30574/wjarr.2021.11.1.0313

Received on 04 June 2021; revised on 05 July 2021; accepted on 09 July 2021

Background: Although PICC plays a crucial role in preterm neonates, it may cause several complications. A pilot study was conducted to propose a useful equation in identifying the safe length of catheter during the first attempt of catheterization.
Methods: A pilot study was carried out and NICU admitted preterm neonates requiring PICC insertion entered the study. PICC was inserted for neonates by an expert NICU nurse. After catheterization, a chest X-ray examination with contrast was done to determine the location of canola. All neonates' demographic data were extracted from medical records. Age of neonate at catheterization, the duration of catheterization period as well as data regarding the first and final sizes of the inserted PICC were also recorded. Finally, the associations between the lengths of catheters with neonates' demographic factors were assessed to propose an equation estimating the optimal length of inserted PICC.
Results: One hundred preterm neonates requiring PICC entered the study. The results have shown significant associations between the first length of inserted catheter in the hand with head circumference (p=0.019; r=0.293) as well as the final length of inserted catheter in the hand with birth weight (p=0.015; r=0.304). There was a linear correlation between the length of inserted catheter in the hand with neonate's birth weight (p=0.029); however, based on the value of R2=0.167, this relationship was weak. According to these findings an equation was proposed as follows; Inserted length in hand (cm) = 17.98 + 0.618body weight (gr).
Conclusion: Our results showed a positive correlation between the inserted lengths of PICC in the hand with neonate's body weight. Our findings proposed an equation; however, the regression coefficient was not significantly notable.

Preterm; Neonates; PICC; Equation; Length

https://wjarr.co.in/sites/default/files/fulltext_pdf/WJARR-2021-0313.pdf

Preview Article PDF

MahbodKaveh, Mohammad SadeghArabhosseini, Mohammad Reza Zarkesh, MokaramehHaghjoo, MaedehRaznaha and Zahra Farahani. A proposed equation estimating the length of peripherally inserted central catheter in hand for NICU hospitalized preterm neonates. World Journal of Advanced Research and Reviews, 2021, 11(01), 044-050. Article DOI: https://doi.org/10.30574/wjarr.2021.11.1.0313

Copyright © 2021 Author(s) retain the copyright of this article. This article is published under the terms of the Creative Commons Attribution Liscense 4.0

Footer menu

  • Contact

Copyright © 2026 World Journal of Advanced Research and Reviews - All rights reserved

Developed & Designed by VS Infosolution